Echo.

Acquire. Recognize. Measure. Integrate.

Educational simulation · clinical review pending

Probe & patient

TTE

Drag the probe across the chest. Its marker sets image orientation.

Surface landmark key
  • Clavicles
  • Suprasternal notch
  • Sternum
  • Ribs & intercostal spaces
  • Xiphoid
  • Physical probe marker
Probe movements & physiology
Spatial anatomy

Drag the heart to rotate. The probe and imaging plane stay fixed.

Parasternal long axisLive · TTE · 0.00 s
In this plane
Select a visible structure to identify it in both displays.
Display options

Drag or rotate the teaching camera. The probe and acquired plane remain fixed.

0.00 s
Image formation controls

Detail stays fixed while scanning; load never silently reduces resolution. Ultra detail adds native samples and takes longer. Freeze for finer sampling before measuring; quality does not change calibration.

Gain changes brightness; TGC compensates by depth. Frequency trades penetration for detail. Focus changes lateral definition; depth and sector width change sampled coverage and rendering work. These are representative acoustic effects.

View guide & acquisition feedback
0 acquisitions recorded locally

Parasternal long axis

Left parasternal interspace, often 3rd–4th; left lateral position

Marker: Patient’s right shoulder

Beam: Across the LV long axis toward its apex

Movements to explore

  • Slide between interspaces to find a window
  • Rock/tilt until LV and aortic root share their long axis
  • Rotate toward the left shoulder for PSAX

Find these landmarks

  • RVOT
  • IVS
  • LV
  • MV
  • LVOT
  • AV
  • LA
  • descending aorta

Adequacy

  • Elongated LV with parallel septum/posterior wall
  • MV and aortic root in continuity
  • Interpret anterior RV as an RVOT section, not global RV size
Common errors & corrective movements
  • An oblique LV slice overstates thickness and distorts RVOT
  • A papillary muscle in this plane suggests off-axis imaging

Measurements & Doppler

  • LV dimensions and wall thickness
  • MV/AV mechanism
  • LA AP dimension
  • Aortic root
  • Effusion distribution

Presets move the virtual probe. Every intermediate pose samples the same patient. Use the probe controls to explore off-axis planes and loss of the acoustic window.

Integrated report

A defensible report integrates the evidence and its limitations. A single number does not need to “win.” Reports save with acquisitions.

Original synthetic model. Anatomy and image formation are simplified; clinical review is pending. Methods & limitations